The EZ Snap Covers Sample includes two pieces of EZ-Snap Covers baseboard heater cover material. Each sample kit will include one Standard height and one tall height piece, one of which will be powder-coated white and the other our Galvanized...
Baseboard Heater Cover: Tall White Solid Coupler Product Code: TWFC-01 If you have extra long baseboards you may need to join them with a coupler. It is very easy so don’t worry about it being difficult. Tall products are 9 1/2"...
Baseboard Heater Cover: Standard White 45 Degree Inside Corner Product Code: SWISC45-01 Used for bay windows and 45-degree angles. When using this corner the cover will need to be cut to length on site by the installer. If you have any...
Baseboard Heater Cover: Tall White Left Open Endcap Product Code: TWLO-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, when pipes or other parts pass through the end cap, use this end cap. Tall size is 9 1/2"...
PRODUCT CODE: 13448
DESCRIPTION : Our covers snap directly over your old existing baseboard heater wall plate. These come a maximum 7 feet long. Covers over 7 feet will require a coupler every 7 feet to couple them together.
Baseboard Heater Cover: Standard White 90 Degree Outside Corner Product Code: SWOSC90-01 Used to connect 2 EZ-Snap™ BaseBoard Covers at an outside or wrap around a corner that is 90 degrees or right angle. When using this corner see measuring instructions...
Baseboard Heater Cover: Standard Galvanized Mesh Coupler Product Code: SGJC-01 If you have extra long baseboards you may need to join them with a coupler. It is very easy so don’t worry about it being difficult. Standard parts are 7 1/2"...
Baseboard Heater Cover: Standard Galvanized Length Panel Product Code: SGBC100 Our covers snap directly over your old existing baseboard heater wall plate. These come a maximum of 7 feet long. Covers over 7 feet will require a coupler every 7...
Baseboard Heater Cover: Standard Galvanized 90 Degree Inside Corner Product Code: SGISC90-01 Used to connect 2 EZ-Snap BaseBoard Covers at an inside corner that is 90 degrees or right angle. When using this corner you need to subtract 3” off the...
Baseboard Heater Cover: Tall White Flush Endcap Product Code: TWFC-01 These end caps are used when you have baseboard butting up against something that prevents use of a normal end cap. They give the look of an end cap but not...
Baseboard Heater Cover: Tall Galvanized Left Closed Endcap Product Code: TGLC-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, do not use this end cap. Tall...
Baseboard Heater Cover: Tall Galvanized Right Closed Endcap Product Code: TGRC-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, do not use this end cap. Tall...
Baseboard Heater Cover: Standard White Italian Pillar Solid Coupler Product Code: SWPSC-01 If you have extra long baseboards you may need to join them with a coupler. It is very easy so don’t worry about it being difficult. Standard products are 7...
Baseboard Heater Cover: Standard White Italian Pillar Right Open Endcap Product Code: SWPRO-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, use this end cap. Standard Size...
Baseboard Heater Cover: Standard White Wavy Gravy Solid Coupler Product Code: SWWSC-01 If you have extra long baseboards you may need to join them with a coupler. It is very easy so don’t worry about it being difficult. Standard products are...
Baseboard Heater Cover: Standard White Italian Pillar Left Open Endcap Product Code: SWPLO-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, use this end cap. Standard Size...
From Standard 7 1/2 to 9 1/2 inch galvanized steel or even custom-sized baseboard heater covers, EZ Snap Covers are the premier provider of baseboard radiator cover kits, parts, and more. Especially known for our products’ easy installation, whether you are replacing old baseboard heater covers, just need a few parts and pieces, or are covering your baseboard radiator for the first time, EZ Snap Covers is here to help. No matter your needs, you can trust that our baseboard heater cover kits and heater cover parts will have better longevity, affordability, and rust- and grime-resistance than any of our competitors’ products.
If you are interested in something more comprehensive than specific baseboard heater cover parts, be sure to also check out our inventory of Easy Pre-Boxed Kits or our Custom Kit Constructor.
Measure Your Baseboard Heaters
How to measure baseboard heaters:
Step 1 HOW TO MEASURE
Always measure left to right, and twice for accuracy
Step 1: Floor to top of Wall plate
Measure the height from the floor to the top of the metal wall plate.
Follow our guide for baseboard heater cover measurement:
Any baseboard larger than 7 3/8" (188 mm) will be compatible with our standard cover.
Any measurement greater than 9 3/8" (238 mm) will fit our tall cover.
Step 2: Bottom of Fintube to Top of Wall Plate
Measure from the bottom of the finned tube heating element to the top of the metal wall plate,
A measurement of 5 1/2" to 6 3/4" (140 mm – 172 mm) will fit our standard cover.
A measurement of 7 1/2" to 8 3/4" (191 mm – 222 mm) will fit our tall cover.
Step 3: Back Wall to Front of Fintube
Measure the distance from the wall or the metal wall plate attached to the wall, to the outside of the finned tube heating element.
Any measurement of less than 3 1/8" (76 mm) inches from the wall will fit our
standard cover.
Any measurement of less than 3 1/8" (76 mm) inches from the wall will fit our tall cover.
Step 2 DETERMINE IF BRACKETS ARE NECESSARY
Always measure left to right, and twice for accuracy
Wall Widget
EZ Snap™ Wall Widgets are used when your old or existing wall back plate has been removed or if you have to hang your new cover 1 inch or higher to bring them up to a height that will fit our installation guidelines. Just measure your overall desired height, subtract 1", drill a hole, preferably in a stud and attach it to the wall with the included screw.
Floor Fidgets
EZ Snap™ Floor Fidgets easily raise your new covers ¾ inch to compensate for any ¾ inch floor (wood, tile, or other) that has been installed any time since your baseboard heater was originally installed. May be used for any reason when the overall height has been shortened and the total height is less than 7-½ inches for standard height or 9-½ inches for the TALL height EZ Snap™ BaseBoard Covers. Just use the self-tapping screws to secure them to the top of your existing wallplate.
Wall Contraptions
EZ Snap™ Wall Contraptions are used when your wall back plate has been completely removed. EZ Snap™ Wall Contraptions receives your EZ Snap™ BaseBoard Cover and keeps your aluminum fin tube from sagging. These completely replace your wall back plate. To install, slide up from the bottom and make sure the top is at your desired height. Screw to the wall, then bend the front finger up to hold the fin tube in place.
Step 3
HOW TO MEASURE LENGTH
Based on how your heater is configured,
choose an option below to expand and view
specific hot water baseboard heater measurement templates.
Measure from wall to wall and subtract ½ inch (to allow for wiggle room when installing your new covers.) The endcaps can be pulled or slid ½ inch outward on either end to fit your existing length requirements. Choose 2 flush to wall end caps.
Measure the overall length of the existing unit with ends attached then subtract ½ inch (to allow for wiggle room when installing your new covers.) The endcaps can be pulled or slid ½ inch outward on either end to fit your existing length requirements. Choose 2 Closed or Open-end caps.
Measure from the corner to the end of the unit with ends attached then subtract ½ inch (to allow for wiggle room when installing your new covers.) The endcaps can be pulled or slid ½ inch outward on either end to fit your existing length requirements. Choose 1 Closed or Open-end & 1 flush to wall end cap.
Measure the left side from corner A to corner B (see diagram). Then subtract 3 inches for the 90 degree inside corner, then subtract another ½ inch (to allow for wiggle room when installing your new covers.) Repeat for the right side if also wall to wall. You need to subtract a total of 3½ inches from each side that is wall to wall. Choose your end caps.
Measure the left side from the corner of the wall to the end of the unit with ends caps. Then subtract 3 inches for the 90 degree inside corner, then subtract another ½ inch (to allow for wiggle room when installing your new covers.) Repeat for the right side. You need to subtract a total of 3½ inches from both left and right sides. Choose your end caps.
L-Shaped outside radiators ending in the middle of the wall: Measure from outside corner of the wall A to the end of the radiator unit with end caps attached B, then subtract ½" (to allow for wiggle room when installing your new covers.)
Left leg - measure from the corner out to the end of the radiator subtract 3" for the corner and ½ (to allow for wiggle room when installing your new covers.)
Center leg - measure from corner to corner and subtract 3" for each corner a total of 6"
Right leg - measure from the corner out to the end of the radiator subtract 3" for the corner and ½" (to allow for wiggle room when installing your new covers.).
We recommend that you order covers a little longer than normal and cut them on site, as there are many opportunities for mistakes in measuring and installation. By cutting on site you can fit and cut to fit. The covers can be cut with a good quality jigsaw and a fine metal cutting blade.
TWO SIDES HAVE SPACES AND WRAP AROUND WALL TO WALL SECTIONS
Measure from the corner of the wall to the outside corner. Subtract 3" for the 90 degree corner (for both left and right legs). Measure from the corner to the end of the unit with end caps on. Subtract 3" for the 90 degree corner then subtract ½" for wiggle room.