PRODUCT CODE: 13448 DESCRIPTION : Our covers snap directly over your old existing baseboard heater wall plate. These come a maximum 7 feet long. Covers over 7 feet will require a coupler every 7 feet to couple them together. 8 Foot...
Baseboard Heater Cover: Standard White Left Closed Endcap Product Code: SWLC-01 If your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, you’ll need our baseboard heater end caps. These baseboard end caps attach to the end of your new...
Baseboard Heater Cover: Standard White Right Closed Endcap Product Code: SWRC-01 Does your EZ-Snap™ BaseBoard Cover end in the middle of a wall? Instead of leaving a gap or uneven finish where your baseboard cover ends, our baseboard end caps provide...
Baseboard Heater Cover: Standard White Left Open Endcap Product Code: SWLO-01 Used when your EZ-Snap™ Baseboard Cover ends in the middle of a wall, when pipes or other parts pass through the end cap, use this end cap. Standard Size is...
Baseboard Heater Cover: Standard White Right Open Endcap Product Code: SWRO-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, when pipes or other parts pass through the end cap, use this end cap. Standard size is...
Baseboard Heater Cover: Standard White Left Flush Endcap
Product Code: SWFC-01
Used when your EZ-Snap™ BaseBoard Cover ends or butts against a wall, pipes can go through wall or not go through wall. Standard height is 7 1/2".
Baseboard Heater Cover: Standard White Right Flush Endcap
Product Code: SWFC-01
Used when your EZ-Snap™ BaseBoard Cover ends or butts against a wall, pipes can go through wall or not go through wall. Standard height is 7 1/2".
Baseboard Heater Cover: Standard White Flush Endcap
Product Code: SWFC-01
Used when your EZ-Snap™ BaseBoard Cover ends or butts against a wall, pipes can go through wall or not go through wall.
Baseboard Heater Cover: Standard White Italian Pillar Left Closed Endcap Product Code: SWPLC-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, do not use this end...
Baseboard Heater Cover: Standard White Italian Pillar Right Closed Endcap Product Code: SWPRC-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, do not use this end cap....
Baseboard Heater Cover: Standard White Italian Pillar Left Open Endcap Product Code: SWPLO-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, use this end cap. Standard Size...
Baseboard Heater Cover: Standard White Italian Pillar Right Open Endcap Product Code: SWPRO-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, use this end cap. Standard Size...
Baseboard Heater Cover: Standard White Wavy Gravy Left Closed Endcap Product Code: SWWLC-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, do not use this end cap. ...
Baseboard Heater Cover: Standard White Wavy Gravy Right Closed Endcap Product Code: SWWRC-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, do not use this end...
Baseboard Heater Cover: Standard White Wavy Gravy Left Open Endcap Product Code: SWWLO-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, use this end cap. Standard Size...
Baseboard Heater Cover: Standard White Wavy Gravy Right Open Endcap Product Code: SWWRO-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, use this end cap. Standard Size...
Do you need to order individual EZ Snap™ Covers baseboard heater cover parts? Check out our category of individual white standard-size parts. You can buy all parts you need individually outside of a Custom Kit. We provide 3 different endcaps, 4 different corner angles, and 3 different brackets, so you can get exactly what you’re looking for! You can search baseboard radiator cover parts by type or cover.
These parts fit perfectly over 7 1/2 inch baseboard heaters. They add modern style to your heater, and they accent any white décor in your home. Plus, baseboard heater cover parts create a safer environment for children and pets while extending radiator longevity.
Our All-American-made covers also support the Wounded Warrior Project and Dogs on Deployment. We are proud to support these two great organizations that assist military personnel.
EZ Snap™ products definitely compliment your home. Shop EZ Snap™ standard white baseboard radiator cover parts today!
Measure Your Baseboard Heaters
How to measure baseboard heaters:
Step 1 HOW TO MEASURE
Always measure left to right, and twice for accuracy
Step 1: Floor to top of Wall plate
Measure the height from the floor to the top of the metal wall plate.
Follow our guide for baseboard heater cover measurement:
Any baseboard larger than 7 3/8" (188 mm) will be compatible with our standard cover.
Any measurement greater than 9 3/8" (238 mm) will fit our tall cover.
Step 2: Bottom of Fintube to Top of Wall Plate
Measure from the bottom of the finned tube heating element to the top of the metal wall plate,
A measurement of 5 1/2" to 6 3/4" (140 mm – 172 mm) will fit our standard cover.
A measurement of 7 1/2" to 8 3/4" (191 mm – 222 mm) will fit our tall cover.
Step 3: Back Wall to Front of Fintube
Measure the distance from the wall or the metal wall plate attached to the wall, to the outside of the finned tube heating element.
Any measurement of less than 3 1/8" (76 mm) inches from the wall will fit our
standard cover.
Any measurement of less than 3 1/8" (76 mm) inches from the wall will fit our tall cover.
Step 2 DETERMINE IF BRACKETS ARE NECESSARY
Always measure left to right, and twice for accuracy
Wall Widget
EZ Snap™ Wall Widgets are used when your old or existing wall back plate has been removed or if you have to hang your new cover 1 inch or higher to bring them up to a height that will fit our installation guidelines. Just measure your overall desired height, subtract 1", drill a hole, preferably in a stud and attach it to the wall with the included screw.
Floor Fidgets
EZ Snap™ Floor Fidgets easily raise your new covers ¾ inch to compensate for any ¾ inch floor (wood, tile, or other) that has been installed any time since your baseboard heater was originally installed. May be used for any reason when the overall height has been shortened and the total height is less than 7-½ inches for standard height or 9-½ inches for the TALL height EZ Snap™ BaseBoard Covers. Just use the self-tapping screws to secure them to the top of your existing wallplate.
Wall Contraptions
EZ Snap™ Wall Contraptions are used when your wall back plate has been completely removed. EZ Snap™ Wall Contraptions receives your EZ Snap™ BaseBoard Cover and keeps your aluminum fin tube from sagging. These completely replace your wall back plate. To install, slide up from the bottom and make sure the top is at your desired height. Screw to the wall, then bend the front finger up to hold the fin tube in place.
Step 3
HOW TO MEASURE LENGTH
Based on how your heater is configured,
choose an option below to expand and view
specific hot water baseboard heater measurement templates.
Measure from wall to wall and subtract ½ inch (to allow for wiggle room when installing your new covers.) The endcaps can be pulled or slid ½ inch outward on either end to fit your existing length requirements. Choose 2 flush to wall end caps.
Measure the overall length of the existing unit with ends attached then subtract ½ inch (to allow for wiggle room when installing your new covers.) The endcaps can be pulled or slid ½ inch outward on either end to fit your existing length requirements. Choose 2 Closed or Open-end caps.
Measure from the corner to the end of the unit with ends attached then subtract ½ inch (to allow for wiggle room when installing your new covers.) The endcaps can be pulled or slid ½ inch outward on either end to fit your existing length requirements. Choose 1 Closed or Open-end & 1 flush to wall end cap.
Measure the left side from corner A to corner B (see diagram). Then subtract 3 inches for the 90 degree inside corner, then subtract another ½ inch (to allow for wiggle room when installing your new covers.) Repeat for the right side if also wall to wall. You need to subtract a total of 3½ inches from each side that is wall to wall. Choose your end caps.
Measure the left side from the corner of the wall to the end of the unit with ends caps. Then subtract 3 inches for the 90 degree inside corner, then subtract another ½ inch (to allow for wiggle room when installing your new covers.) Repeat for the right side. You need to subtract a total of 3½ inches from both left and right sides. Choose your end caps.
L-Shaped outside radiators ending in the middle of the wall: Measure from outside corner of the wall A to the end of the radiator unit with end caps attached B, then subtract ½" (to allow for wiggle room when installing your new covers.)
Left leg - measure from the corner out to the end of the radiator subtract 3" for the corner and ½ (to allow for wiggle room when installing your new covers.)
Center leg - measure from corner to corner and subtract 3" for each corner a total of 6"
Right leg - measure from the corner out to the end of the radiator subtract 3" for the corner and ½" (to allow for wiggle room when installing your new covers.).
We recommend that you order covers a little longer than normal and cut them on site, as there are many opportunities for mistakes in measuring and installation. By cutting on site you can fit and cut to fit. The covers can be cut with a good quality jigsaw and a fine metal cutting blade.
TWO SIDES HAVE SPACES AND WRAP AROUND WALL TO WALL SECTIONS
Measure from the corner of the wall to the outside corner. Subtract 3" for the 90 degree corner (for both left and right legs). Measure from the corner to the end of the unit with end caps on. Subtract 3" for the 90 degree corner then subtract ½" for wiggle room.