PRODUCT CODE: 117 DESCRIPTION : For each coupler 7’ ¼” and above we will calculate into the total, the cost of a coupler. For each additional 7’ in length ( 14’,21’,28’…..) we will add 1 coupler to that order, for you...
Baseboard Heater Cover: Tall Galvanized Left Closed Endcap Product Code: TGLC-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, do not use this end cap. Tall...
Baseboard Heater Cover: Tall Galvanized Right Closed Endcap Product Code: TGRC-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, if pipes or other parts pass through the end cap, do not use this end cap. Tall...
Baseboard Heater Cover: Tall Galvanized Left Open Endcap Product Code: TGLO-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, when pipes or other parts pass through the end cap, use this end cap. Tall size parts are...
Baseboard Heater Cover: Tall Galvanized Right Open Endcap Product Code: TGRO-01 Used when your EZ-Snap™ BaseBoard Cover ends in the middle of a wall, when pipes or other parts pass through the end cap, use this end cap. Tall size parts are 9 1/2"...
Baseboard Heater Cover: Tall Galvanized Left Flush Endcap
Product Code: TGFC-01
Used when your EZ-Snap™ BaseBoard Cover ends or butts against a wall, pipes can go through wall or not go through wall. Tall height is 9 1/2".
Baseboard Heater Cover: Tall Galvanized Right Flush Endcap
Product Code: TGFC-01
Used when your EZ-Snap™ BaseBoard Cover ends or butts against a wall, pipes can go through wall or not go through wall. Tall height is 9 1/2".
Baseboard Heater Cover: Tall Galvanized Flush Endcap
Product Code: TGFC-01
Used when your EZ-Snap™ BaseBoard Cover ends or butts against a wall, pipes can go through the wall or not go through the wall. Tall products are 9 1/2" tall.
Baseboard Heater Cover: Tall Galvanized Mesh Coupler Product Code: TGJC-01 Used to couple any 2 EZ-Snap™ BaseBoard Covers that are over 7 feet …made out of the same perforated 20 Gauge galvanized steel as the covers. Tall products are 9 1/2"...
Baseboard Heater Cover: Tall Galvanized Solid Coupler Product Code: TGFC-01 If you have extra long baseboards you may need to join them with a coupler. It is very easy so don’t worry about it being difficult. Tall products are 9 1/2" tall....
Baseboard Heater Cover: Tall Galvanized 90 Degree Inside Corner Product Code: TGISC90-01 Used to connect 2 EZ-Snap™ BaseBoard Covers at an inside corner that is 90 degrees or right angle. When using this corner you need to subtract 3” off the...
Baseboard Heater Cover: Tall Galvanized 90 Degree Outside Corner Product Code: TGOSC90-01 Used to connect 2 EZ-Snap™ BaseBoard Covers at an outside or wrap around corner that is 90 degrees or right angle. When using this corner see measuring instructions for...
Baseboard Heater Cover: Tall Galvanized 45 Degree Inside Corner Product Code: TGISC45-01 Used for bay windows and 45 degree angles. When using this corner the cover will need to be cut to length on site by the installer. If you have...
Baseboard Heater Cover: Tall Galvanized 45 Degree Outside Corner Product Code: TGOSC45-01 Used to connect 2 EZ-Snap™ BaseBoard Covers at an outside or wrap around corner that is 45 degrees angle. Used for bay or bow windows. When using this corner...
Baseboard Heater Cover: Bracket - Wall Widget Product Code: UBWWB-01 EZ-Snap™ Wall Widgets are used when your old or existing wall back plate has been removed or if you have to hang your new cover 1 inch or higher to bring...
Baseboard Heater Cover: Floor Fidget Bracket Product Code: UBFFB-01 EZ-Snap™ Floor Fidgets easily raise your new covers ¾ inch to compensate for any ¾ inch floor (wood ,tile or other) that has been installed any time since your baseboard heater was...
Don't need the complete custom kit? Purchase individual galvanized standard size parts for your baseboard heater cover installation. You can specify your preferences for corners, brackets, couplers, and endcaps when you buy our 9 ½” inch baseboard heater galvanized cover parts. Don’t let your baseboard rust or burn people or animals; our tall galvanized baseboard heater cover parts can prevent all of that! They also keep your heater in great shape!
EZ Snap™ covers are made with the strongest, thickest galvanized steel and epoxy powder coated covers made. Our tall galvanized baseboard heater cover parts will fit perfectly on your baseboard—and installation won’t require a plumber or HVAC contractor.
We’re a proud partner of the Wounded Warrior Project and Dogs on Deployment. Your investment in our products contributes toward these two great causes!
Purchase EZ Snap™ 9 ½”-inch baseboard heater galvanized cover parts today to make your life more convenient with a great investment!
Measure Your Baseboard Heaters
How to measure baseboard heaters:
Step 1 HOW TO MEASURE
Always measure left to right, and twice for accuracy
Step 1: Floor to top of Wall plate
Measure the height from the floor to the top of the metal wall plate.
Follow our guide for baseboard heater cover measurement:
Any baseboard larger than 7 3/8" (188 mm) will be compatible with our standard cover.
Any measurement greater than 9 3/8" (238 mm) will fit our tall cover.
Step 2: Bottom of Fintube to Top of Wall Plate
Measure from the bottom of the finned tube heating element to the top of the metal wall plate,
A measurement of 5 1/2" to 6 3/4" (140 mm – 172 mm) will fit our standard cover.
A measurement of 7 1/2" to 8 3/4" (191 mm – 222 mm) will fit our tall cover.
Step 3: Back Wall to Front of Fintube
Measure the distance from the wall or the metal wall plate attached to the wall, to the outside of the finned tube heating element.
Any measurement of less than 3 1/8" (76 mm) inches from the wall will fit our
standard cover.
Any measurement of less than 3 1/8" (76 mm) inches from the wall will fit our tall cover.
Step 2 DETERMINE IF BRACKETS ARE NECESSARY
Always measure left to right, and twice for accuracy
Wall Widget
EZ Snap™ Wall Widgets are used when your old or existing wall back plate has been removed or if you have to hang your new cover 1 inch or higher to bring them up to a height that will fit our installation guidelines. Just measure your overall desired height, subtract 1", drill a hole, preferably in a stud and attach it to the wall with the included screw.
Floor Fidgets
EZ Snap™ Floor Fidgets easily raise your new covers ¾ inch to compensate for any ¾ inch floor (wood, tile, or other) that has been installed any time since your baseboard heater was originally installed. May be used for any reason when the overall height has been shortened and the total height is less than 7-½ inches for standard height or 9-½ inches for the TALL height EZ Snap™ BaseBoard Covers. Just use the self-tapping screws to secure them to the top of your existing wallplate.
Wall Contraptions
EZ Snap™ Wall Contraptions are used when your wall back plate has been completely removed. EZ Snap™ Wall Contraptions receives your EZ Snap™ BaseBoard Cover and keeps your aluminum fin tube from sagging. These completely replace your wall back plate. To install, slide up from the bottom and make sure the top is at your desired height. Screw to the wall, then bend the front finger up to hold the fin tube in place.
Step 3
HOW TO MEASURE LENGTH
Based on how your heater is configured,
choose an option below to expand and view
specific hot water baseboard heater measurement templates.
Measure from wall to wall and subtract ½ inch (to allow for wiggle room when installing your new covers.) The endcaps can be pulled or slid ½ inch outward on either end to fit your existing length requirements. Choose 2 flush to wall end caps.
Measure the overall length of the existing unit with ends attached then subtract ½ inch (to allow for wiggle room when installing your new covers.) The endcaps can be pulled or slid ½ inch outward on either end to fit your existing length requirements. Choose 2 Closed or Open-end caps.
Measure from the corner to the end of the unit with ends attached then subtract ½ inch (to allow for wiggle room when installing your new covers.) The endcaps can be pulled or slid ½ inch outward on either end to fit your existing length requirements. Choose 1 Closed or Open-end & 1 flush to wall end cap.
Measure the left side from corner A to corner B (see diagram). Then subtract 3 inches for the 90 degree inside corner, then subtract another ½ inch (to allow for wiggle room when installing your new covers.) Repeat for the right side if also wall to wall. You need to subtract a total of 3½ inches from each side that is wall to wall. Choose your end caps.
Measure the left side from the corner of the wall to the end of the unit with ends caps. Then subtract 3 inches for the 90 degree inside corner, then subtract another ½ inch (to allow for wiggle room when installing your new covers.) Repeat for the right side. You need to subtract a total of 3½ inches from both left and right sides. Choose your end caps.
L-Shaped outside radiators ending in the middle of the wall: Measure from outside corner of the wall A to the end of the radiator unit with end caps attached B, then subtract ½" (to allow for wiggle room when installing your new covers.)
Left leg - measure from the corner out to the end of the radiator subtract 3" for the corner and ½ (to allow for wiggle room when installing your new covers.)
Center leg - measure from corner to corner and subtract 3" for each corner a total of 6"
Right leg - measure from the corner out to the end of the radiator subtract 3" for the corner and ½" (to allow for wiggle room when installing your new covers.).
We recommend that you order covers a little longer than normal and cut them on site, as there are many opportunities for mistakes in measuring and installation. By cutting on site you can fit and cut to fit. The covers can be cut with a good quality jigsaw and a fine metal cutting blade.
TWO SIDES HAVE SPACES AND WRAP AROUND WALL TO WALL SECTIONS
Measure from the corner of the wall to the outside corner. Subtract 3" for the 90 degree corner (for both left and right legs). Measure from the corner to the end of the unit with end caps on. Subtract 3" for the 90 degree corner then subtract ½" for wiggle room.